{"title":"All Products","description":"","products":[{"product_id":"1-2-coupling-for-lineset","title":"Couplings","description":"\u003cp\u003eThe coupling joins equal size copper refrigeration tubing by means of a permanent mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe coupling is ETL listed for U.S. and Canada with an allowable working pressure of 1500 PSIG per UL-207. The coupling is intended for use with C12200 Type L copper tube conforming to dimensions of ASTM B280. All tempers of copper tube may be used (O60, H55, H58). Coupling may also be used with C19400 copper alloy.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e1500 psi (100 bar)\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":46354228445341,"sku":"BCPL-02","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/k0rT-6kr.jpg?v=1769132423"},{"product_id":"press-tool-kit-with-1-4-through-1-1-8-clamps","title":"RCS Press Tool Kit","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe RCS-2623 tool kit is an 18V handheld battery-powered hydraulic axial press tool system designed for copper refrigerant tubing systems up to 1 1\/8” O.D.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTool Kit Components:\u003c\/strong\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\u003cspan\u003e1 ea. 26 kN Hand Tool\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\u003cspan\u003e2 ea. Batteries 2.0Ah, 18V, Li-Ion\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\u003cspan\u003e1 ea. Charger 115V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e1\/4\" \u0026amp; 3\/8\" – 1\/2\" ” Combo Clamps\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e5\/8” - 3\/4\" Combo Clamps\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e7\/8” - 1 1\/8\" Combo Clamps\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" style=\"font-weight: bold;\"\u003e\n\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eDesigned for use with \u003ca rel=\"noopener\" href=\"https:\/\/refrigerantcouplingsystems.com\/products\/1-2-coupling-for-lineset\" target=\"_blank\"\u003eRCS Press Fittings\u003c\/a\u003e Only.\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLIMITATIONS Not for use in hazardous, explosive, or wet environments. The assembly of gas pipes in gas distribution line with this tool is prohibited. For use by qualified \u0026amp; trained professionals only.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":46298863468701,"sku":"RCS-2623","price":2249.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/tool_kit.png?v=1768536309"},{"product_id":"digital-tube-bender-5-8-to-1-3-8-with-tripod","title":"Digital Tube Bender 5\/8\" to 1-3\/8\" with Tripod","description":"\u003ch3\u003eCHARACTERISTICS\u003c\/h3\u003e\n\u003cp\u003eAngle Capacity: 190⁰1.7kw \/ 2.3 HP, 120VAC \/ 1 phase\u003cbr\u003eDimensions: 25”L x 10”W x 7.5”D\u003cbr\u003eNet Weight: 31 lb.Digital Readout Display 0⁰-180⁰ for repetitive bends\u003cbr\u003eAutomatic stop at predetermined angle. Set with thumb screw. Displayed on digital readout\u003cbr\u003eHigh reduction gear box for increased torque\u003cbr\u003eLow friction guide shoe\u003cbr\u003eForward and Reverse switch\u003cbr\u003eBends made at 3.5 RPM with soft start\u003c\/p\u003e\n\u003ch3\u003eTUBING SIZE RANGE\u003c\/h3\u003e\n\u003cp\u003e5\/8” OD, Bend Radius = 2.5”\u003cbr\u003e3\/4” OD, Bend Radius = 3.0”\u003cbr\u003e7\/8” OD, Bend Radius = 3.5”\u003cbr\u003e1-1\/8” OD, Bend Radius = 4.5”\u003cbr\u003e1-3\/8” OD, Bend Radius = 4.8”\u003c\/p\u003e\n\u003ch3\u003eTOOL KIT COMPONENTS\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 ea. DB32 Electric Tubing Bender\u003c\/li\u003e\n\u003cli\u003e1 ea. Tripod Mounting Stand\u003c\/li\u003e\n\u003cli\u003e1 ea. Back Former Mounting Post\u003c\/li\u003e\n\u003cli\u003eBending Formers and Back Formers for:\n\u003cul\u003e\n\u003cli\u003e5\/8” OD ACR (Bendable Quality)\u003c\/li\u003e\n\u003cli\u003e3\/4” OD ACR (Bendable Quality)\u003c\/li\u003e\n\u003cli\u003e7\/8” OD ACR (Bendable Quality)\u003c\/li\u003e\n\u003cli\u003e1-1\/8” OD ACR (Bendable Quality)\u003c\/li\u003e\n\u003cli\u003e1-3\/8” OD ACR (Bendable Quality)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 ea. Carrying Case for Bender and Formers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLIMITATIONS\u003c\/h3\u003e\n\u003cp\u003eUse ONLY with O60 annealed or H55 Light Drawn ACR copper tubing with OD as listed above.\u003c\/p\u003e\n\u003cp\u003eDO NOT BEND H58 GENERAL PURPOSE DRAWN.\u003c\/p\u003e\n\u003cp\u003eDO NOT unbend a previous bend. This will cause tube failure.\u003c\/p\u003e\n\u003cp\u003eThe tool operates at tremendous forces and can cause severe damage or injury.\u003c\/p\u003e\n\u003cp\u003eFor use by professionally trained technician only.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":46298863501469,"sku":"DB32","price":2889.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/TA-DB32ElectricTubeBenderKit.jpg?v=1734988684"},{"product_id":"4-in-1-spring-loaded-tube-cutter-1-4-through-1-1-4","title":"4-in-1 Spring Loaded Tube Cutter 1\/4\" through 1 1\/4\"","description":"\u003cp\u003e4 in 1 Constant Tension Mini Tube Cutter\u003cbr\u003eSpring-Loaded, 6-32 mm (1\/4\" - 1-1\/4\")\u003cbr\u003eExtension handle\u003cbr\u003eLubricated rollers\u003cbr\u003eHSS Cutting blade\u003cbr\u003eDeburring tool\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":46298863534237,"sku":"RTC-46324","price":61.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/tube_cutter3.jpg?v=1746117199"},{"product_id":"rcs-tube-depth-insertion-gage","title":"RCS Tube Depth Insertion Gage","description":"\u003cp\u003e\u003cstrong\u003eRCS-TIG\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepth gauge to accurately marks and confirms the proper insertion depth of the tubing prior to making the final connection (¼” through 1-5\/8” tubes).\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":46298863567005,"sku":"RCS-TIG","price":7.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/DepthInsertionGage1.jpg?v=1738955942"},{"product_id":"loctite-648-anaerobic-compound-50ml-bottle","title":"LOCTITE 648 Anaerobic Compound","description":"\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eLOCTITE® 648™ is designed for the bonding of cylindrical fitting parts. The product cures when confined in the absence of air between close fitting metal surfaces and prevents loosening and leakage from shock and vibration. LOCTITE® 648™ provides robust curing performance. It not only works on active metals (e.g. mild steel) but also on passive substrates such as stainless steel and plated surfaces. The product offers high temperature performance and oil tolerance. It tolerates minorsurface contaminations from various oils, such as cutting, lubrication, anti-corrosion and protection fluids.\u003c\/p\u003e\n\u003ch3\u003eLIMITATIONS\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis product is not recommended for use in pure oxygen and\/or oxygen rich systems and should not be selected as a sealant for chlorine or other strong oxidizing materials.\u003c\/li\u003e\n\u003cli\u003eFor safe handling information on this product, consult the Safety Data Sheet (SDS).\u003c\/li\u003e\n\u003cli\u003eWhere aqueous washing systems are used to clean the surfaces before bonding, it is important to check for compatibility of the washing solution with the adhesive. In some cases these aqueous washes can affect the cure and performance of the adhesive.\u003c\/li\u003e\n\u003cli\u003eThis product is not normally recommended for use on plastics (particularly thermoplastic materials where stress cracking of the plastic could result). Users are recommended to confirm compatibility of the product with such substrates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSTORAGE\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStore product in the unopened container in a dry location. Storage information may be indicated on the product container labeling.\u003c\/li\u003e\n\u003cli\u003eOptimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties. Material removed from containers may be contaminated during use.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":46384220668061,"sku":"CL-648-50ML","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/Loctite_648__UGK6_v1.jpg?v=1734988558"},{"product_id":"reducer-for-lineset","title":"Reducers","description":"\u003cp\u003eThe reducer joins unequal size copper refrigeration tubing by means of a permanent mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe reducer is ETL listed for U.S. and Canada with an allowable working pressure of 1500 PSIG per UL-207. The reducer is intended for use with C12200 Type L copper tube conforming to dimensions of ASTM B280. All tempers of copper tube may be used (O60, H55, H58). Coupling may also be used with C19400 copper alloy.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e1500 psi (100 bar)\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"3\/8\" to 1\/4\"","offer_id":46357137653917,"sku":"BRED-9302","price":15.13,"currency_code":"USD","in_stock":true},{"title":"1\/2\" to 3\/8\"","offer_id":46357137686685,"sku":"BRED-9493","price":19.33,"currency_code":"USD","in_stock":true},{"title":"5\/8\" to 1\/2\"","offer_id":46357137719453,"sku":"BRED-9594","price":21.2,"currency_code":"USD","in_stock":true},{"title":"3\/4\" to 5\/8\"","offer_id":46357137752221,"sku":"BRED-9695","price":26.3,"currency_code":"USD","in_stock":true},{"title":"7\/8\" to 3\/4\"","offer_id":46357137784989,"sku":"BRED-9607","price":32.42,"currency_code":"USD","in_stock":true},{"title":"1 1\/8\" x 7\/8\"","offer_id":46434002272413,"sku":"BRED-0907","price":41.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/RCS_Website_Images-74.jpg?v=1768839008"},{"product_id":"cold-shrink-sleeve-5-pack","title":"Cold Shrink Sleeve","description":"\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eThe CS92 Cold Shrink Protective Sleeve is an open ended silicone rubber sleeve pre-expanded and assembled onto a plastic removable core. The plastic core is removed when the sleeve is positioned for installation over an RCS mechanically attached fitting. Silicone Cold Shrink is used to protect the steel collars used on RCS fittings from moisture when installed under thermal insulation.\u003c\/p\u003e\n\u003cp\u003eThis cold shrink tube is recommended for all RCS fittings installed on insulated piping located outdoors and on all RCS fittings used at the piping connection to VRF outdoor units.\u003c\/p\u003e\n\u003cp\u003eThese sleeves should also be installed on RCS fittings wherever the piping insulation cannot be installed per the insulation manufacturer’s instructions.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eLocate the plastic core pull strip on the cold shrink and note the pull direction orientation.\u003c\/li\u003e\n\u003cli\u003eIMPORTANT: Slide the Cold Shrink sleeve onto the tubing section to be joined before installing the RCS mechanically attached fittings. Make sure that adequate space is available to remove the plastic core in later step.\u003c\/li\u003e\n\u003cli\u003eInstall the RCS fitting per the detailed installation instructions.\u003c\/li\u003e\n\u003cli\u003eAfter pressure and leak testing has shown the fitting joint to be acceptable, center the Cold Shrink sleeve on the fitting to be covered.\u003c\/li\u003e\n\u003cli\u003ePull the plastic strip slowly in the direction labeled on the Cold Shrink sleeve and allow the rubber sleeve on the opposite end to shrink onto the tube at the predetermined position on the copper tube.\u003c\/li\u003e\n\u003cli\u003eAfter the rubber sleeve takes firm hold of the tube, continue to pull the strip smoothly till the entire plastic core is removed and the rubber sleeve is in complete contact with the copper tube and the enclosed fitting.\u003c\/li\u003e\n\u003cli\u003eInsulate the piping system as required following the insulation manufacturer’s detailed instructions\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":46357143945373,"sku":"CSS-0502-5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/RCS_Website_Images-54.jpg?v=1734810853"},{"product_id":"end-cap","title":"End Cap","description":"\u003cp\u003eThese fittings cap (blank off) copper refrigeration tubing by means of a permanent mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe cap is ETL listed for U.S. and Canada with an allowable working pressure of 1500 PSIG per UL-207. The cap is intended for use with C12200 Type L copper tube conforming to dimensions of ASTM B280. All tempers of copper tube may be used (O60, H55, H58). Coupling may also be used with C19400 copper alloy.\u003c\/p\u003e\n\u003cp\u003ePorted pressure test cap with 1\/8” NPT Schrader valve available in sizes 5\/8, 3\/4, 7\/8, and 1 1\/8 inch.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e1500 psi (100 bar)\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVED\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47572626702493,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/RCS_Website_Images-69.jpg?v=1768838916"},{"product_id":"flare-kit","title":"Flare Kit","description":"\u003cp\u003eThese kits connect copper refrigeration tubing to the mechanical equipment by means of a permanent mechanical seal to a JIS B 8607 Class 2 Flare Stub. To ensure equipment compatibility, this kit is designed to utilize the factory Flare Nut provided with the original equipment.\u003c\/p\u003e\n\u003cp\u003eThe fitting is ETL listed for U.S. and Canada with an allowable working pressure of 1500 PSIG per UL-207. The copper flare stub allowable working pressure is equal to the annealed copper tube rating by tube size per ASME B31.5. The fitting is intended for use with C12200 Type L copper tube conforming to dimensions of ASTM B280. All tempers of copper tube may be used (O60, H55, H58). Fitting may also be used with C19400 copper alloy.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e600 psi\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe flare nut is NOT included with the kit. The factory flare nut must be used and installed prior to final installation of the flare coupling.\u003c\/p\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47572649771165,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/RCSWebsiteImages-65.jpg?v=1768838869"},{"product_id":"isolation-valves","title":"Isolation Valves","description":"\u003cp\u003eThe full port ball valve connects to copper refrigeration tubing by means of a permanent mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe valve is supplied with straight ends configuration, ETL listed for U.S. and Canada with an allowable working pressure of 700 PSIG per UL-207. The valve is compatible with all Group A1 refrigerants and all refrigeration oils. The valve is internally equalized ball design, full port, bi-directional flow, with PTFE rupture-proof encapsulated stem seals.\u003c\/p\u003e\n\u003cp\u003eThe fitting is ETL listed for U.S. and Canada with an allowable working pressure of 1500 PSIG per UL-207. The fitting is intended for use with C12200 Type L copper tube conforming to dimensions of ASTM B280. All tempers of copper tube may be used (O60, H55, H58). Fitting may also be used with C19400 copper alloy.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e700 psi\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3 and directive 2014\/68EU.\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eInstallation The couplings are shipped loose for field installation on to the valve. The valve is supplied with line size couplings with special tube support adaptor inserts for the valve side (Black), standard inserts for the lineside (Clear\/Silver), and a 3\/4 inch thick insulation jacket.\u003c\/p\u003e\n\u003cp\u003eThe valve and fittings must be installed per both RCS and NDL, Inc. installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47572652490909,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/V_ON_METUS.jpg?v=1769133406"},{"product_id":"h55-copper-tubes","title":"H55 Copper Tubes","description":"\u003cdiv class=\"woocommerce-product-details__short-description\"\u003e\n\u003cp\u003eCopper is C12200, Seamless, Light Drawn (H55), Type L, ACR\/MED bendable quality tubing, conforming to ASTM B75. The copper tube meets dimensional, chemical, mechanical strength, cleanliness, and eddy current testing requirements of ASTM B280 and ASTM B819 as applicable.\u003c\/p\u003e\n\u003cp\u003eLight drawn (H55) tubing is a bendable quality tube in straight lengths, approved for field bending without annealing.\u003c\/p\u003e\n\u003cp\u003eTube ends are sealed with plugs to maintain cleanliness.\u003c\/p\u003e\n\u003cp\u003eAllowable strength per ASME B31.5-2016 Table 502.3.1\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eALLOWABLE STRENGTH*\u003c\/h3\u003e\n\u003cp\u003e10,300 psi (10.3 ksi) at 250⁰F per ASM B31.5-2016 when used with mechanically attached fittings.\u003c\/p\u003e\n\u003ch3\u003eSTANDARDS\u003c\/h3\u003e\n\u003cp\u003eASTM B75, ASTM B280, and ASTM B819\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe tubing is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe tubing is not suitable for use with ammonia (R 717) or Methyl Chloride (R40) refrigerants.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe tubing must be installed by skilled installers, trained in the application and installation of H55 (half hard) temper copper tubing and RCS fittings.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47572655079581,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/copper-pipes-625x417.webp?v=1768534424"},{"product_id":"psp45-battery-powered-press-system-package","title":"PSP45 Battery Powered Press System Package","description":"\u003cp\u003eThe PSP45-18 Battery Powered Press Tool package is a powerful tooling system is designed for convenient, fast, and reliable pressing system of linear type flame-free mechanically attached fittings. By combining a high quality powerful hydraulic tool with long lasting Lithium-Ion battery, rapid charging technology, and RCS quick-change clamps and inserts system in to a total tooling packaged solution, field installation of RCS fittings can be safely, consistently, and efficiently made. This tooling system also works on most currently available linear-press type fittings in the HVAC and refrigeration market today.\u003c\/p\u003e\n\u003cp\u003eThe packaged tooling system consist of two specially designed kits, the hydraulic press tool kit with its companion 18 volt battery and charger, and the quick-change clamps and inserts kit with sliding clamps and tool inserts to fit 1\/4 through 1 5\/8 inch fittings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKL45KN Battery Powered Press Toolkit:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 ea. 45 KN Hand Tool\u003c\/li\u003e\n\u003cli\u003e1 ea. 4 Amp-HR, 18V, Li-Ion Battery\u003c\/li\u003e\n\u003cli\u003e1 ea. Battery Rapid Charger\u003c\/li\u003e\n\u003cli\u003e1 ea. Carrying Case with Operation Instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRCS18PC Quick-Change Clamps \u0026amp; Inserts Kit:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 pair Universal Press Clamps with:\u003c\/li\u003e\n\u003cli\u003e1\/4”-3\/8” Clamp Inserts\n\u003cul\u003e\n\u003cli\u003e1\/2” Clamp Inserts\u003c\/li\u003e\n\u003cli\u003e5\/8” Clamp Inserts\u003c\/li\u003e\n\u003cli\u003e3\/4” Clamp Inserts\u003c\/li\u003e\n\u003cli\u003e7\/8” Clamp Inserts\u003c\/li\u003e\n\u003cli\u003e1-1\/8” Clamp Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 pair 1-3\/8” Dedicated Press Clamps\u003c\/li\u003e\n\u003cli\u003e1 pair 1-5\/8” Dedicated Press Clamps\u003c\/li\u003e\n\u003cli\u003e1 ea. Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLIMITATIONS\u003c\/h3\u003e\n\u003cp\u003eNot for use in hazardous, explosive, or wet environment.The assembly of gas pipes in gas distribution line with this tool is prohibited.For use by qualified \u0026amp; trained professionals only.\u003c\/p\u003e\n\u003cp\u003eThe tool operates at high closing pressure and can cause severe damage or injury.\u003c\/p\u003e\n\u003cp\u003eFor use by professionally trained technician only.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578338984093,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/1_0b13a560-b53b-4bcb-b077-88a41ba06d9d.webp?v=1768841859"},{"product_id":"branch-selector-box-kit","title":"Branch Selector Box Kit","description":"\u003cp\u003eThese kits provide the necessary couplings, reducers, and\/or caps to connect VRF Branch Selector Boxes to outdoor unit piping and indoor unit piping. Each kit is custom built to match the project system selection lay-out as provided by the customer. The couplings, reducers, flare tube kits, or closed pipe caps are shipped loose for field installation on to the selector box.\u003c\/p\u003e\n\u003cp\u003eSpecialty tube support adaptor inserts may be supplied with the kit for proper fit onto certain selector box connecting pipe.\u003c\/p\u003e\n\u003cp\u003eContact RCS customer service team for more details on tube inserts for your selected equipment. Refer to RCS installation instructions for details prior to installing these fittings.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e1167 psi (80 bar)\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVED\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280. Do not use on annealed copper sizes larger than 5\/8” O.D.\u003c\/p\u003e\n\u003ch3\u003eWARNING\u003c\/h3\u003e\n\u003cp\u003eAll equipment manufacturers’ installation restrictions must be strictly followed. The use of RCS flame-free mechanically attached fittings does not relief the installer from following the equipment manufacturers installation requirements.\u003c\/p\u003e\n\u003cp\u003eExcept for factory male flare ends, all factory swaged-ends must be cut off the Selector Box to provide for actual line size in order to install RCS flame-free mechanically attached fittings.\u003c\/p\u003e\n\u003cp\u003eA minimum of 3 ⅛ inches of straight tube clearance from the selector box bulkhead and 1 ⅝ inch clearance between adjacent tubes are required to engage the press tool.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578358120605,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/IMG_2900.jpg?v=1769042504"},{"product_id":"heat-pump-odu-connection-kits","title":"Heat Pump ODU Connection Kits","description":"\u003cp\u003eThese kits provide the necessary couplings and reducers to connect VRF outdoor condensing unit to the refrigerant piping system. Each kit is custom built to match the project system selection lay-out as provided by the customer. The couplings, reducers, and silicone cold shrink sleeves are shipped loose for field installation on to the condensing unit connecting piping. Adequate tool clearance must be confirmed prior to installation. Accessory tubing and Multi-Frame Y-Branch pipe kits are NOT included and must be installed separately.\u003c\/p\u003e\n\u003cp\u003eAll RCS fittings installed outdoors, at the outdoor units, on insulated piping located outdoors, in wet\/humid environments, or wherever the thermal insulation cannot be installed per the insulation manufacturer’s instructions, must be protected from possible corrosion via the use of cold shrink, heat shrink, or other suitable impervious protective cover.\u003c\/p\u003e\n\u003cp\u003eSpecialty tube support inserts may be supplied with the kit for proper fit onto certain condensing unit connecting pipe.\u003c\/p\u003e\n\u003cp\u003eRefer to RCS installation instructions for details prior to installing these fittings.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e1167 psi (80 bar)\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280. Do not use on annealed copper sizes larger than 5\/8” O.D.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578364412061,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/Resized_20200804_082630.jpg?v=1769729015"},{"product_id":"heat-pump-y-branch-pipe-kit","title":"Heat Pump Y-Branch Pipe Kit","description":"\u003cp\u003eThese kits provide the necessary Y-Branch fittings, couplings, reducers, and\/or caps to field erect a VRF refrigerant tubing system by means of permanent mechanical connection. Each kit is custom built to match the project system selection lay-out as provided by the customer. The couplings and reducers are shipped loose for field installation on to the respective Y-Branches. Refer to RCS installation instructions for details prior to installation.\u003c\/p\u003e\n\u003cp\u003e*The copper Y-Branch center fittings are not UL Listed component.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATE PRESSURE\u003c\/h3\u003e\n\u003cp\u003e600 psi\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280. Do not use on annealed copper sizes larger than 5\/8” O.D.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578367590557,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/Y_Branches_cropped-removebg-preview.png?v=1769729071"},{"product_id":"heat-recovery-odu-connection-kits","title":"Heat Recovery ODU Connection Kits","description":"\u003cp\u003eThese kits provide the necessary couplings and reducers to connect VRF outdoor condensing unit to the refrigerant piping system. Each kit is custom built to match the project system selection lay-out as provided by the customer. The couplings, reducers, and silicone cold shrink sleeves are shipped loose for field installation on to the condensing unit connecting piping. Adequate tool clearance must be confirmed prior to installation. Accessory tubing and Multi-Frame Y-Branch pipe kits are NOT included and must be installed separately.\u003c\/p\u003e\n\u003cp\u003eAll RCS fittings installed outdoors, at the outdoor units, on insulated piping located outdoors, in wet\/humid environments, or wherever the thermal insulation cannot be installed per the insulation manufacturer’s instructions, must be protected from possible corrosion via the use of cold shrink, heat shrink, or other suitable impervious protective cover.\u003c\/p\u003e\n\u003cp\u003eSpecialty tube support inserts may be supplied with the kit for proper fit onto certain condensing unit connecting pipe.Refer to RCS installation instructions for details prior to installing these fittings.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e1167 psi (80 bar)\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280. Do not use on annealed copper sizes larger than 5\/8” O.D.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578370834589,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/Resized_20200804_082630.jpg?v=1769729015"},{"product_id":"heat-recovery-y-branch-pipe-kits","title":"Heat Recovery Y-Branch Pipe Kits","description":"\u003cp\u003eThese kits provide the necessary Y-Branch fittings, couplings, reducers, and\/or caps to field erect a VRF refrigerant tubing system by means of permanent mechanical connection. Each kit is custom built to match the project system selection lay-out as provided by the customer. The couplings and reducers are shipped loose for field installation on to the respective Y-Branches. Refer to RCS installation instructions for details prior to installation.\u003c\/p\u003e\n\u003cp\u003e*The copper Y-Branch center fittings are not UL Listed component.\u003c\/p\u003e\n\u003ch3\u003eHIGH PRESSURE\u003c\/h3\u003e\n\u003cp\u003eHVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e600 psi\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280. Do not use on annealed copper sizes larger than 5\/8” O.D.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578378797213,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/Y_Branches_cropped-removebg-preview.png?v=1769729071"},{"product_id":"indoor-unit-connection-kits","title":"Indoor Unit Connection Kits","description":"\u003cp\u003eThese fan coil connection kits are pre-configured combination packages of flare tube kits, couplings, or reducers to connect the liquid and suction lines of fan coils with flare connections and large horizontal outside air units to the piping system.Toensure equipment compatibility, the pre-flared kits are designed to utilize the factory Flare Nut provided with the original equipment.\u003c\/p\u003e\n\u003cp\u003eThe copper flare tube provided with the fitting is annealed (O60) C12200 copper tube and conforms to JIS B 8607 Class 2 dimensional requirements. The copper flared tube allowable working pressure is equal to the annealed copper tube rating by tube size per ASME B31.5.\u003c\/p\u003e\n\u003cp\u003eThe Coupling is ETL listed for U.S. and Canada with an allowable working pressure of 1167 PSIG per UL-207. The fitting is intended for use with C12200 Type L copper tube conforming to ASTM B280. All tempers of copper tube may be used(O60, H55, H58). The fitting may also be connected to C19400 copper alloy.\u003c\/p\u003e\n\u003cp\u003eSpecialty tube support inserts may be supplied with the kit for proper fit onto certain fan coil connecting tubing.Refer to RCS installation instructions for details prior to installing these fittings.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e600 psi\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e\n\u003cp\u003eContact RCS, Inc. for alternative tube support inserts when installing fittings on annealed copper coils or pre-insulated line sets with tube wall thicknesses less than specified by ASTM B280. Do not use on annealed copper sizes larger than 5\/8” O.D.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578383745181,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/AFLR_Kit.2.jpg?v=1769042403"},{"product_id":"multi-frame-heat-pump-unit-pipe-kit","title":"Multi-Frame Heat Pump Unit Pipe Kit","description":"\u003cp\u003eThese kits are braze-free alternative to the equipment manufacturer Outdoor Unit Multi Connection Pipe Kits. These outdoor pipe kits provide the necessary Y-Branch fittings, couplings, reducers, to field connect dual and triple frame VRF outdoor units to the refrigerant tubing system by means of permanent mechanical connection. Each kit is custom built to match the project system selection lay-out as provided by the customer.\u003c\/p\u003e\n\u003cp\u003eThe Y-branch, couplings, reducers, and silicone cold shrink sleeves are shipped loose for installation on to the field piping. Accessory tubing and outdoor unit connectors are NOT included and must be installed separately.\u003c\/p\u003e\n\u003cp\u003eAll RCS fittings installed outdoors, at the outdoor units, on insulated piping located outdoors, in wet\/humid environments, or wherever the thermal insulation cannot be installed per the insulation manufacturer’s instructions, must be protected from possible corrosion via the use of cold shrink, heat shrink, or other suitable impervious protective cover.\u003c\/p\u003e\n\u003cp\u003eRefer to RCS installation instructions for details prior to installation.*The copper Y-Branch center fittings are not UL Listed component\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e600 psi\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578386006173,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/Y_Branches_cropped-removebg-preview.png?v=1769729071"},{"product_id":"multi-frame-heat-recovery-unit-pipe-kit","title":"Multi-Frame Heat Recovery Unit Pipe Kit","description":"\u003cp\u003eThese kits are braze-free alternative to the equipment manufacturer Outdoor Unit Multi Connection Pipe Kits. These outdoor pipe kits provide the necessary Y-Branch fittings, couplings, reducers, to field connect dual and triple frame VRF outdoor units to the refrigerant tubing system by means of permanent mechanical connection. Each kit is custom built to match the project system selection lay-out as provided by the customer.\u003c\/p\u003e\n\u003cp\u003eThe Y-branch, couplings, reducers, and silicone cold shrink sleeves are shipped loose for installation on to the field piping. Accessory tubing and outdoor unit connectors are NOT included and must be installed separately.\u003c\/p\u003e\n\u003cp\u003eAll RCS fittings installed outdoors, at the outdoor units, on insulated piping located outdoors, in wet\/humid environments, or wherever the thermal insulation cannot be installed per the insulation manufacturer’s instructions, must be protected from possible corrosion via the use of cold shrink, heat shrink, or other suitable impervious protective cover. Refer to RCS installation instructions for details prior to installation.\u003c\/p\u003e\n\u003cp\u003e*The copper Y-Branch center fittings are not UL Listed component.\u003c\/p\u003e\n\u003ch3\u003eAPPLICATION\u003c\/h3\u003e\n\u003cp\u003eHigh Pressure HVAC\/R\u003c\/p\u003e\n\u003ch3\u003eMAX RATED PRESSURE\u003c\/h3\u003e\n\u003cp\u003e600 psi\u003c\/p\u003e\n\u003ch3\u003eCOMPATIBLE TUBING\u003c\/h3\u003e\n\u003cp\u003eSeamless Copper Tubing, Drawn H58, Light Drawn H55, or Annealed O60 made to ASTM B280 and ASTM B75 Standard.\u003c\/p\u003e\n\u003ch3\u003eAGENCY APPROVAL\u003c\/h3\u003e\n\u003cp\u003eETL Listed 5011885. Conforms to UL 207 STD. Certified to CSA STD C22.2#140.3\u003c\/p\u003e\n\u003ch3\u003eREFRIGERANTS\u003c\/h3\u003e\n\u003cp\u003eAll CFC, HCFC, HFC, HFO, and class A2L refrigerants and refrigeration oils.\u003c\/p\u003e\n\u003cp\u003eThe product is suitable for use with R744 (CO2) when used within the design pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe product is not suitable for use with ammonia, methyl chloride, hazardous or flammable refrigerants from Group 2 or 3 per ASHRAE 15.\u003c\/p\u003e\n\u003ch3\u003eINSTALLATION\u003c\/h3\u003e\n\u003cp\u003eThe fittings must be installed per RCS installation instructions by skilled installers, trained specifically in the application and installation of RCS fittings.\u003c\/p\u003e","brand":"RefrigerantCouplingSystems.com","offers":[{"title":"Default Title","offer_id":47578391117981,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/8692\/7261\/files\/Y_Branches_cropped-removebg-preview.png?v=1769729071"}],"url":"https:\/\/www.refcouplingsys.com\/collections\/all-products.oembed?page=2","provider":"RefrigerantCouplingSystems.com","version":"1.0","type":"link"}